高(gao)壓(ya)試(shi)驗變壓(ya)器在(zai)進行高(gao)壓(ya)試(shi)驗時(shi)遵守(shou)的規程(cheng)
更(geng)新(xin)時(shi)間(jian):2023-06-29
點(dian)擊次數(shu):1162
高(gao)壓(ya)試(shi)驗變壓(ya)器在(zai)進行高(gao)壓(ya)試(shi)驗時(shi)遵守(shou)的規程(cheng)
1、高(gao)壓(ya)試(shi)驗應填(tian)寫(xie)種(zhong)工作(zuo)票(piao)。在(zai)壹(yi)個電氣(qi)連接部分同時(shi)有檢(jian)修(xiu)和(he)試(shi)驗時(shi)填(tian)壹(yi)張(zhang)工(gong)作(zuo)票(piao)。但(dan)在(zai)試(shi)驗前(qian)應得到(dao)檢(jian)修工作(zuo)負責(ze)員(yuan)的許可(ke),在(zai)同壹(yi)電氣(qi)連部分,高(gao)壓(ya)試(shi)驗的(de)工(gong)作(zuo)票(piao)發出(chu)後(hou),禁止(zhi)再發第二(er)張(zhang)工(gong)作(zuo)票(piao)。如加壓(ya)部分和檢(jian)修部分之間(jian)的斷(duan)開(kai)點(dian),按(an)試(shi)驗電(dian)壓(ya)有足夠的距離(li),並在(zai)另壹(yi)側有(you)接短路(lu)時,串聯(lian)諧振(zhen)可(ke)在(zai)斷(duan)開(kai)點(dian)壹(yi)側進(jin)行試(shi)驗,另壹(yi)側可(ke)繼續工(gong)作(zuo),但(dan)此(ci)時(shi)在(zai)斷(duan)開(kai)點(dian)應掛(gua)有“止(zhi)步(bu),高(gao)壓(ya)危險(xian)!"標示(shi)牌(pai),並(bing)設(she)有(you)專人(ren)監(jian)護;
2、高(gao)壓(ya)試(shi)驗工(gong)作(zuo)不(bu)許少於(yu)兩人(ren),試(shi)驗負責(ze)人(ren)應由有(you)經驗(yan)的(de)人(ren)員擔任(ren),開(kai)始(shi)試(shi)驗前(qian)試(shi)驗負責(ze)人(ren)應對全體試(shi)驗人(ren)員(yuan)詳(xiang)細布(bu)置試(shi)驗中(zhong)的註意事(shi)項(xiang);
3、因(yin)試(shi)驗需(xu)要(yao)斷(duan)開(kai)設(she)備(bei)接頭時,拆(chai)前(qian)應做(zuo)好標記(ji),接後(hou)應進行檢(jian)查;
4、試(shi)驗裝(zhuang)置的(de)金(jin)屬(shu)外(wai)殼應接地(di),高(gao)壓(ya)引線(xian)應盡(jin)量(liang)縮(suo)短(duan),必要(yao)時(shi)用絕(jue)緣(yuan)物(wu)支持牢(lao)固(gu),試(shi)驗裝(zhuang)置的(de)電(dian)源(yuan)開(kai)關應使(shi)明顯斷(duan)開(kai)的雙刀(dao)閘(zha),為(wei)了(le)防止(zhi)誤合,切(qie)閘(zha),可(ke)在(zai)刀刃(ren)上(shang)加絕緣(yuan)罩,試(shi)驗裝(zhuang)置的(de)低(di)壓(ya)回路(lu)中(zhong)應有兩個串聯(lian)電源(yuan)開(kai)關,並(bing)加上(shang)裝(zhuang)過載(zai)自(zi)動掉閘(zha)裝(zhuang)置;
5、試(shi)驗現(xian)場應裝(zhuang)設(she)遮(zhe)欄(lan)或(huo)圍欄(lan),向(xiang)外(wai)懸掛(gua)“止(zhi)步(bu),高(gao)壓(ya)危險(xian)!"標牌(pai)並(bing)派(pai)人看(kan)守,被試(shi)設(she)備(bei)兩端(duan)不(bu)在(zai)同壹(yi)地(di)點(dian)時,另壹(yi)點(dian)應派(pai)人看(kan)守;
6、加壓(ya)前(qian),認(ren)真檢(jian)查,試(shi)驗接線(xian)表計(ji)倍率(lv),調(tiao)壓(ya)器在(zai)零位及(ji)儀(yi)表(biao)的開(kai)始(shi)狀態,均正(zheng)確無(wu)誤(wu),通(tong)知(zhi)有(you)關人員離(li)開(kai)被試(shi)設(she)備(bei),並取(qu)得負責(ze)人(ren)許可(ke),方可(ke)加壓(ya),加壓(ya)中(zhong)應有監護並(bing)呼唱(chang),高(gao)壓(ya)試(shi)驗工(gong)作(zuo)人(ren)員(yuan),在(zai)全部加壓(ya)中(zhong),應精力集中(zhong)不得與(yu)他(ta)人(ren)閑(xian)談(tan),隨時(shi)警惕異(yi)常現(xian)象發生。操作(zuo)人(ren)員(yuan)應站(zhan)在(zai)絕緣(yuan)墊上(shang);
7、變更(geng)接線(xian)或(huo)試(shi)驗結(jie)束時,應首先斷(duan)開(kai)試(shi)驗電(dian)源(yuan),放電(dian)並(bing)將升壓(ya)設(she)備(bei)的高(gao)壓(ya)部分短路(lu)落地(di);
8、未(wei)裝(zhuang)地(di)線(xian)的大(da)熔(rong)器被試(shi)設(she)備(bei),應先放電(dian)再做(zuo)試(shi)驗,高(gao)壓(ya)直流試(shi)驗時(shi),每(mei)告(gao)壹(yi)段落(luo)或(huo)結(jie)束,應將設(she)備(bei)對地(di)放電(dian)數(shu)次,並(bing)短路接地(di);
9、試(shi)驗結(jie)束時,試(shi)驗人(ren)員(yuan)應拆(chai)除自(zi)裝(zhuang)的接地(di)短(duan)路(lu)線(xian),並對被試(shi)設(she)備(bei)進行檢(jian)查和清(qing)理現(xian)場;
10、特殊(shu)的(de)重要(yao)電(dian)氣(qi)試(shi)驗,應有詳(xiang)細的(de)試(shi)驗措(cuo)施(shi)並(bing)經(jing)主管(guan)生產領導(dao)(總工)批(pi)準(zhun)。