交直(zhi)流高壓(ya)試(shi)驗變(bian)壓(ya)器(qi)現(xian)場(chang)試(shi)驗註意(yi)事項(xiang)
1、使(shi)用(yong)前(qian)請(qing)認(ren)真閱讀高壓(ya)試(shi)驗變(bian)壓(ya)器(qi)使(shi)用(yong)說(shuo)明書;
2、先(xian)接(jie)好(hao)高壓(ya)變(bian)壓(ya)器(qi)到控(kong)制(zhi)臺的連(lian)接(jie)線(xian)、高壓(ya)變(bian)壓(ya)器(qi)到被(bei)試(shi)品的連(lian)線(xian)及地(di)線最(zui)後(hou)接(jie)通(tong)電(dian)源(yuan)線(xian);
3、高壓(ya)變(bian)壓(ya)器(qi)、控制(zhi)臺和被(bei)試(shi)品三(san)者(zhe)的(de)地(di)線均(jun)需可(ke)靠(kao)連(lian)接(jie);
4、請(qing)確(que)保高壓(ya)試(shi)驗變(bian)壓(ya)器(qi)和控(kong)制(zhi)臺之間(jian)的輸(shu)入(ru)、輸(shu)出(chu)和(he)測(ce)量(liang)線不(bu)要(yao)接(jie)錯(cuo)5、因整個系統(tong)容(rong)量(liang)很(hen)大,選(xuan)擇(ze)與(yu)電(dian)流相(xiang)適(shi)應(ying)的電(dian)纜線(xian);
6、高壓(ya)試(shi)驗變(bian)壓(ya)器(qi)、控制(zhi)箱(xiang)、被(bei)試(shi)品和人之間(jian)必須保證(zheng)必要(yao)的(de)安全(quan)距(ju)離(li)。安全(quan)距(ju)離(li)具體值(zhi)請(qing)根(gen)據試(shi)驗電(dian)壓(ya)查閱相(xiang)關的(de)安全(quan)手冊(ce);
7、在(zai)合(he)閘之前,請(qing)把(ba)調壓(ya)器(qi)手柄調到(dao)零(ling)位(wei)再(zai)合(he)閘;
8、高壓(ya)試(shi)驗變(bian)壓(ya)器(qi)的短接(jie)銅桿(gan)插(cha)入(ru)為(wei)輸(shu)出(chu)交流,拔出(chu)為(wei)直(zhi)流輸(shu)出(chu),電(dian)壓(ya)表(biao)讀(du)數時請(qing)註(zhu)意(yi)交直(zhi)流;
9、查明過流原(yuan)因並采(cai)取(qu)有效(xiao)措(cuo)施(shi)後(hou)再進(jin)行(xing)耐壓(ya)試(shi)驗;10、在升(sheng)壓(ya)過(guo)程(cheng)中請(qing)密(mi)切註意(yi)電(dian)壓(ya)表(biao)的(de)讀數,切勿(wu)超過(guo)系(xi)統(tong)的(de)額(e)定最高電(dian)壓(ya);
11、試(shi)驗結束(shu)後(hou),必須將調壓(ya)器(qi)回至(zhi)零(ling)位,切斷(duan)電(dian)源(yuan),用(yong)放(fang)電(dian)棒放電(dian)後(hou)再接(jie)觸(chu)高壓(ya)變(bian)壓(ya)器(qi)、控制(zhi)臺及被(bei)試(shi)品;
12、在(zai)試(shi)驗過程(cheng)中,如(ru)出(chu)現(xian)異(yi)常(chang)情況(kuang)(如(ru)異(yi)響(xiang)、焦(jiao)味、冒煙(yan)等),應(ying)立即(ji)切(qie)斷(duan)電(dian)源(yuan),檢(jian)查原(yuan)因(yin)。故障排除(chu)後(hou)方可(ke)再進(jin)行(xing)耐壓(ya)試(shi)驗;
13、如(ru)果(guo)接(jie)地(di)故障指示(shi)燈(deng)亮,則(ze)檢(jian)查接(jie)地(di)線是否(fou)安(an)全(quan)可(ke)靠(kao);
14、在(zai)試(shi)驗區周圍必須用(yong)警示(shi)帶(dai)或圍欄圍住壹個安全(quan)區(qu)域(yu),並有(you)相(xiang)應(ying)的聲光(guang)報(bao)警,以(yi)防(fang)無關人(ren)員(yuan)靠(kao)近;
15、試(shi)驗員(yuan)必須配(pei)置(zhi)相(xiang)應(ying)電(dian)壓(ya)等(deng)級(ji)的防(fang)護(hu)用(yong)品,無相(xiang)應(ying)操(cao)作(zuo)資(zi)質和不(bu)熟(shu)悉(xi)儀器(qi)的人(ren)員(yuan)請(qing)勿(wu)進行(xing)操(cao)作(zuo);
16、以(yi)上(shang)各(ge)條如(ru)與(yu)相(xiang)關標準和(he)規程(cheng)有(you)抵(di)觸(chu),請(qing)參(can)照(zhao)相(xiang)關的(de)標準和(he)規程(cheng)。